Cleaver Brooks Industrial Gas Burner Assembly - 700HP Boiler Rated - Complete with Controls

Cleaver Brooks Industrial Gas Burner Assembly - 700HP Boiler Rated - Complete with Controls

Contact us for price

Location:Ohio

Description

OVERVIEW

 

NOTE: This is the burner assembly only. The boiler has been sold separately. Burner was removed from service in operational condition.

 

Cleaver Brooks industrial natural gas burner assembly removed from Burnham 700HP three-pass steam generator. Professional-grade packaged burner system featuring integrated Cleaver Brooks control panel with Hawk digital interface, complete burner housing, combustion air fan assembly, and all safety controls. Rated for 29,291 MBH input capacity (700 HP equivalent boiler application) with proven forced-draft design for efficient, reliable combustion. Features complete gas train, flame safeguard system, integrated control panel with digital monitoring, and professional-grade construction. Skid-mounted configuration with all electrical components, motors, and safety interlocks installed. Previously operated on Burnham Model 3P-700-50-LB boiler, now available as standalone burner package. Heavy-duty industrial construction ideal for large commercial boilers, industrial steam generators, process heating applications, or any operation requiring high-capacity natural gas burner with modern digital controls and proven Cleaver Brooks reliability.

 

EQUIPMENT SPECIFICATIONS

 

Burner Model Information:

  • Manufacturer: Cleaver Brooks
  • Type: Industrial natural gas burner
  • Configuration: Forced-draft packaged burner
  • Previous Application: 700 HP steam boiler
  • Fuel Type: Natural Gas
  • Input Capacity: 29,291 MBH (approximate)
  • Origin: USA

 

Performance Ratings:

  • Input Capacity: 29,291 MBH
  • Boiler Rating: 700 HP equivalent
  • Steam Generation: 24,150 lbs/hr (previous application)
  • Fuel: Natural Gas
  • Combustion Type: Forced draft
  • Application Pressure: 150 PSI rated (previous boiler)

 

Control Systems:

  • Control Panel: Cleaver Brooks integrated
  • Digital Interface: Cleaver Brooks Hawk system
  • Flame Safeguard: Integrated system
  • Pressure Monitoring: Gauges installed
  • Safety Interlocks: Complete system
  • Warning/Alarm Indicators: Installed
  • Automated Controls: Full automation package

 

Electrical Components:

  • Combustion Air Motor: Industrial-grade
  • Control Power: 120V circuit
  • Main Power: Per motor specifications
  • Safety Disconnect: Red emergency switch
  • Control Panel: Integrated electrical
  • Wiring: Professional installation

 

Physical Configuration:

  • Mounting: Skid-mounted assembly
  • Burner Housing: Complete assembly
  • Combustion Air Fan: Installed
  • Gas Train: Complete with valves
  • Control Panel: Integrated on burner
  • Color: Teal/turquoise industrial finish
  • Construction: Heavy-duty steel

 

KEY FEATURES & BENEFITS

 

Cleaver Brooks Quality Manufacturing:

  • Premium USA burner manufacturer
  • Industrial-grade construction
  • Proven reliability in demanding applications
  • Heavy-duty commercial design
  • Professional engineering
  • Long service life components
  • Quality craftsmanship throughout

 

High-Capacity Performance:

  • 29,291 MBH input rating
  • 700 HP boiler application rated
  • Heavy-duty industrial capacity
  • Forced-draft combustion design
  • High-efficiency gas firing
  • Reliable high-volume operation
  • Continuous duty rated
  • Commercial/industrial grade

 

Advanced Digital Controls:

  • Cleaver Brooks Hawk interface
  • Digital monitoring and display
  • Real-time operational data
  • Diagnostic capabilities
  • User-friendly operation
  • Professional control panel
  • Safety system integration
  • Automated operation

 

Complete Packaged System:

  • Integrated burner assembly
  • Combustion air fan installed
  • Complete gas train
  • Control panel integrated
  • All safety systems installed
  • Electrical components complete
  • Skid-mounted configuration
  • Ready for installation

 

Natural Gas Efficiency:

  • Natural gas-fired operation
  • Clean-burning fuel
  • Efficient combustion design
  • Lower emissions profile
  • Economical operation
  • Reliable gas-fired performance
  • Professional gas train
  • Optimized combustion

 

Proven Service History:

  • Removed from operational boiler
  • Maintained service records
  • Professional removal
  • Previously on 700 HP boiler
  • 150 PSI steam application
  • Burnham boiler compatibility proven
  • Industrial facility operation
  • Regular maintenance performed

 

Safety & Compliance:

  • Complete flame safeguard system
  • Multiple safety interlocks
  • Emergency disconnect switch
  • Gas pressure monitoring
  • Flame supervision
  • Safety valve systems
  • Code-compliant construction
  • Professional safety engineering

 

Skid-Mounted Design:

  • Complete assembly on skid
  • Integrated mounting system
  • Simplified installation
  • Professional configuration
  • All components secured
  • Ready for rigging
  • Foundation mounting provisions
  • Transportable assembly

 

SYSTEM COMPONENTS

 

Burner Assembly:

  • Cleaver Brooks burner housing
  • Complete combustion head
  • Gas delivery system
  • Burner nozzle assembly
  • Ignition system
  • Flame detection
  • Air/fuel mixing system
  • Professional construction

 

Combustion Air System:

  • Industrial forced-draft fan
  • Air damper controls
  • Combustion air ducting
  • Motor and drive assembly
  • Air pressure monitoring
  • Linkage and controls
  • Professional installation

 

Control Systems:

  • Cleaver Brooks control panel
  • Hawk digital interface
  • Burner management system
  • Flame safeguard controls
  • Operational diagnostics
  • Temperature monitoring
  • Pressure monitoring
  • Safety interlocks

 

Electrical Components:

  • Combustion air motor
  • Control power transformer
  • Safety disconnect switch (red)
  • All wiring and connections
  • Circuit protection
  • Control panel electrical
  • Professional installation
  • Emergency shutoff provisions

 

Safety & Instrumentation:

  • Flame safeguard system
  • Pressure gauges
  • Gas pressure switches
  • Flame supervision
  • Safety interlocks
  • Emergency shutdown capability
  • Warning indicators
  • Alarm systems

 

Gas System:

  • Complete gas train
  • Gas pressure regulation
  • Manual gas valve
  • Safety shut-off valves
  • Gas pressure switches
  • Gas piping connections
  • Safety interlocks
  • Professional gas components

 

Mounting System:

  • Heavy-duty burner skid
  • Structural steel base
  • All components mounted
  • Foundation provisions
  • Rigging points
  • Professional assembly
  • Ready for installation

 

SPECIFICATIONS SUMMARY

 

Burner:

  • Manufacturer: Cleaver Brooks
  • Type: Industrial natural gas burner
  • Configuration: Forced-draft packaged
  • Input: 29,291 MBH (approximate)
  • Boiler Rating: 700 HP application
  • Fuel: Natural Gas
  • Mounting: Skid-mounted
  • Origin: USA
  • Condition: Used, operational

 

Controls:

  • Panel: Cleaver Brooks integrated
  • Interface: Hawk digital system
  • Safety: Flame safeguard system
  • Automation: Complete control package

 

Physical:

  • Color: Teal/turquoise
  • Mounting: Skid configuration
  • Construction: Steel industrial
  • Assembly: Complete package

 

Previous Application:

  • Boiler: Burnham 3P-700-50-LB
  • Capacity: 700 HP
  • Pressure: 150 PSI
  • Steam: 24,150 lbs/hr
  • Service: Industrial facility

 

ADDITIONAL INFORMATION

 

  • Condition: Used - Removed from Operational Service
  • Manufacturer: Cleaver Brooks
  • Burner Type: Industrial Natural Gas Forced-Draft
  • Input Capacity: 29,291 MBH (approximate)
  • Previous Boiler Application: 700 HP / 24,150 lbs/hr steam
  • Fuel Type: Natural Gas
  • Control System: Cleaver Brooks with Hawk digital interface
  • Mounting: Complete skid-mounted assembly
  • Color: Industrial teal/turquoise finish

 

Safety Features:

  • Complete flame safeguard system
  • Multiple safety interlocks
  • Emergency disconnect switch (red)
  • Gas pressure monitoring
  • Flame supervision
  • Safety shut-off valves
  • Alarm and warning systems
  • Professional safety controls

 

Removal Information:

  • Previously installed on Burnham 700HP boiler
  • Boiler has been sold separately
  • Burner removed in operational condition
  • Professional dismounting completed
  • All components intact
  • Control systems included
  • Ready for new installation

 

Installation Notes:

  • Complete packaged burner assembly
  • Skid-mounted for easy installation
  • All electrical components included
  • Gas train complete with safety valves
  • Control panel integrated
  • Requires site preparation
  • Professional rigging recommended
  • Foundation mounting provisions included

 

Features:

  • Cleaver Brooks industrial burner design
  • 29,291 MBH input capacity
  • 700 HP boiler application rated
  • Natural gas-fired operation
  • Forced-draft combustion system
  • Heavy-duty industrial construction
  • Complete packaged assembly
  • Integrated control panel
  • Cleaver Brooks Hawk digital interface
  • Burner management system
  • Flame safeguard controls
  • Professional electrical package
  • Combustion air fan and motor
  • Complete gas train with safety valves
  • Emergency disconnect switch
  • All safety trim and controls installed
  • Pressure gauges and monitoring
  • Warning and alarm indicators
  • Skid-mounted configuration
  • Professional removal from operational boiler
  • Previously on Burnham 700HP boiler
  • Proven reliability in industrial application
  • 150 PSI rated application
  • Ready for natural gas connection
  • Burner assembly only - boiler sold separately
  • Removed from operational service in working condition
  • Professional-grade commercial/industrial construction

Specifications

ManufacturerCleaver Brooks
ConditionUsed
Stock NumberBICB700HP267
* ManufacturerCleaver Brooks
* TypeIndustrial natural gas burner
* Previous Application700 HP steam boiler
* Fuel TypeNatural Gas