Fulton Electric Feed Water Tank System 140 Gallon HF-100 (2009)

Fulton Electric Feed Water Tank System 140 Gallon HF-100 (2009)

Contact us for price

Location:Ohio

Description

Overview


This Fulton HF-100 is a premium electric feed water tank system designed for critical steam boiler applications requiring deaerated and conditioned feed water. This 2009 unit is new and has never been used, featuring twin 100 HP pumps and a 140-gallon tank capacity. The system is engineered to extend boiler life by reducing oxygen levels and contaminants in boiler feed water, making it ideal for brewery, food processing, medical laboratory, and pharmaceutical manufacturing applications.


Design and Performance


  • Manufacturer: Fulton Thermal Corporation
  • Model: HF-100 (Electric Feed Water Tank)
  • Year: 2009
  • Condition: NEW/NEVER USED
  • Serial Number: B53DR-5241
  • Type: Duplex Return System with Pump Selector
  • Tank Capacity: 140 Gallons
  • Construction: Heavy-duty industrial grade with tan/beige finish


Key Specifications


Condition

  • New - Never Used
  • Complete turnkey system
  • Factory assembled and tested
  • Current replacement value: Over $30,000 (2024 pricing)

Performance Features

  • Deaerates feed water to reduce oxygen content
  • Removes contaminants from boiler feed water
  • Extends boiler life significantly
  • Twin pump redundancy for continuous operation
  • Electric heating elements for temperature control
  • Suitable for soft water, treated water, or reverse osmosis input

Pump Configuration

  • Pump Type: Twin Duplex Configuration
  • Pump Capacity: 100 HP each
  • Redundancy: Full backup capability
  • Control: Pump selector for automatic or manual operation
  • Pressure Gauges: Individual pump discharge monitoring


System Components


Feed Water Tank Package Includes

  • 140-gallon ASME-rated pressure vessel
  • Twin 100 HP centrifugal pumps
  • Electric control panel with pump selector
  • Pressure relief valves
  • Temperature monitoring system
  • Level control system
  • Inlet spray nozzles for deaeration
  • Outlet connections for boiler feed
  • Structural steel frame/skid
  • Complete piping and valving

Control Features

  • Digital control interface
  • Pump selector switch (Auto/Manual)
  • System status indicators
  • Temperature controls
  • Level controls
  • Safety interlocks
  • Alarm capabilities


Electrical Requirements


Power Specifications

  • Electric heating system
  • Control voltage requirements per wiring diagram
  • Motor starters for twin pumps
  • Full electrical panel included


Safety Features


  • ASME code pressure vessel
  • Pressure relief valves
  • Temperature limit controls
  • Level safety controls
  • Pump protection systems
  • Emergency shutdown capability
  • Warning labels and safety placards


Applications


Ideal Industries

  • Brewery Operations: Consistent steam for brewing processes
  • Food Processing: Clean steam for cooking and sterilization
  • Medical Laboratories: Pure steam for autoclaves and sterilization
  • Pharmaceutical Manufacturing: USP-grade steam production
  • General Manufacturing: Any process requiring high-quality steam

Benefits

  • Extends boiler life by removing dissolved oxygen
  • Reduces boiler chemical treatment requirements
  • Prevents boiler corrosion and pitting
  • Maintains consistent feed water temperature
  • Reduces boiler thermal shock
  • Improves overall system efficiency
  • Provides feed water storage capacity
  • Twin pump redundancy ensures continuous operation


Water Quality Requirements


Input Water Specifications

  • Soft water from water softener system
  • Treated water from chemical treatment system
  • Reverse osmosis (RO) water for highest purity
  • Must meet boiler manufacturer's feed water specifications

Output Benefits

  • Reduced oxygen content (deaerated)
  • Consistent temperature feed water
  • Removal of dissolved gases
  • Improved boiler efficiency
  • Extended equipment life


Installation Requirements


Space Requirements

  • Adequate clearance for pump maintenance
  • Access to electrical connections
  • Proper ventilation for heat dissipation
  • Level, stable floor capable of supporting full weight

Utility Connections

  • Electrical power supply
  • Feed water inlet piping
  • Boiler feed outlet piping
  • Overflow/drain connections
  • Vent connections


Maintenance Features


  • Easy access to pumps for service
  • Removable panels for internal inspection
  • Standard pump seals and bearings
  • Gauge glass for visual level indication
  • Accessible control components
  • Standard replacement parts availability


Additional Information


Value Proposition

  • 2009 unit in new, unused condition
  • Current 2024 replacement cost exceeds $30,000
  • Significant savings versus new equipment
  • Complete system ready for installation
  • Ideal for expanding operations or backup system

Transaction Details

  • Location: Fresno, California
  • Payment: Cash or bank wire transfer only
  • Industrial-grade equipment
  • Buyer responsible for shipping/transportation


Technical Support


  • Wiring diagram included (B53DR-5241)
  • Fulton factory support available
  • Standard Fulton replacement parts
  • Compatible with all steam boiler systems


Compliance & Standards

  • ASME pressure vessel certification
  • UL listed electrical components
  • National Board registered
  • Meets all applicable codes for:
  • Brewery operations
  • Food processing facilities
  • Medical facilities
  • Pharmaceutical manufacturing

Specifications

ManufacturerFulton
ModelHF-100
Year2009
ConditionNew
Serial NumberB53DR-5241
Stock NumberTFWF140G231