Cleaver Brooks 250 HP 150 PSI Packaged Steam Boiler Natural Gas CB-100-200 (1981)

Cleaver Brooks 250 HP 150 PSI Packaged Steam Boiler Natural Gas CB-100-200 (1981)

Contact us for price

Location:Ohio

Description

Overview


This Cleaver Brooks CB-100-200 packaged steam boiler was manufactured on August 5, 1981. With 250 horsepower capacity (8,369,000 BTU/HR input) and 150 PSI maximum working pressure, this natural gas-fired steam boiler includes integrated burner assembly, 10 HP blower motor, control systems, and factory-insulated jacket on skid-mounted base.


Design and Performance


Boiler Specifications:


  • Manufacturer: Cleaver Brooks (Aqua-Chem Inc.)
  • Model: CB-100-200
  • Serial Number: L-71372
  • Manufacturing Date: 8/5/81
  • UL File Number: R-991648


Pressure and Capacity Ratings:


  • Maximum Pressure: 150 PSI
  • Input Rating: 8,369,000 BTU/HR
  • Horsepower: 250 HP (calculated)
  • Fuel Type: Natural Gas
  • Blower Motor: 10 HP


Electrical Requirements:


  • Main Power Supply: 230 Volts, 3-Phase, 60 Hz, 28 Amp
  • Minimum Circuit Ampacity: 35 Amp
  • Maximum Rating of Circuit Protection: 112 Amp
  • Control Circuit: 120 Volts, 1-Phase, 60 Hz, 7 Amp
  • Oil Pump Motor: 115 Volts, 1-Phase, 60 Hz, 7 Amp


Construction:


  • Packaged steam boiler design
  • Insulated jacket panels
  • Skid-mounted base
  • Front access door
  • Rear access panels
  • Aqua/teal painted finish
  • Integrated burner assembly
  • Pressure gauge mounting points
  • Sight glass ports


System Components:


  • Cleaver Brooks CB-100-200 steam boiler
  • Integrated natural gas burner
  • 10 HP blower motor assembly
  • Control panel with switches
  • Oil pump motor system
  • Pressure gauges
  • Safety valve
  • Electrical junction boxes
  • Insulated jacket panels
  • Sight glass viewing ports
  • Valve manifolds and piping connections


Control Features:


  • Integrated control panel
  • Flame safeguard system
  • Operating indicator lights
  • Burner management controls
  • Safety switches


Safety Features:


  • UL Listed (File #R-991648)
  • Integral primary safety controls
  • Pressure relief valve
  • Flame monitoring
  • Circuit protection systems
  • Safety interlocks


Key Specifications


  • Condition: Used - 1981 Manufacture
  • Brand: Cleaver Brooks
  • Model: CB-100-200
  • Serial Number: L-71372
  • UL File: R-991648
  • Manufacturing Date: 8/5/81
  • Equipment Type: Packaged Steam Boiler


Performance Data:


  • Horsepower: 250 HP
  • Input: 8,369,000 BTU/HR
  • Maximum Pressure: 150 PSI
  • Fuel Type: Natural Gas
  • Blower Motor: 10 HP


Electrical Specifications:


  • Main Supply: 230V, 3-Phase, 60Hz, 28A
  • Minimum Circuit Ampacity: 35A
  • Maximum Circuit Protection: 112A
  • Control Circuit: 120V, 1-Phase, 60Hz, 7A
  • Oil Pump Motor: 115V, 1-Phase, 60Hz, 7A


Physical Specifications:


  • Configuration: Packaged steam boiler
  • Mounting: Skid base
  • Jacket: Insulated panel construction
  • Color: Aqua/teal painted finish
  • Access: Front and rear doors/panels


Burner Specifications:


  • Type: Integrated natural gas burner
  • Gas Input: 8,369,000 BTU/HR
  • Blower Motor: 10 HP
  • Controls: Flame safeguard system


Ideal Applications


  • Commercial Buildings
  • Institutional Facilities
  • Manufacturing Plants
  • Schools and Universities
  • Hospitals and Healthcare Facilities
  • Office Buildings
  • Apartment Complexes
  • Food Processing Plants
  • Laundries and Dry Cleaners
  • Warehouses
  • District Heating Systems
  • Process Steam Requirements
  • Industrial Process Applications


Benefits


  • 1981 Cleaver Brooks manufacture
  • 250 HP steam capacity
  • Natural gas fired
  • 150 PSI maximum pressure
  • 8.369 MMBtu input
  • UL Listed for safety
  • Packaged design
  • 10 HP blower motor included
  • Integrated control system
  • Insulated jacket construction
  • Skid-mounted base
  • Factory-assembled unit
  • Sight glass viewing capability
  • Front and rear access


Additional Information


  • Condition: Used - 1981 Manufacture
  • Manufacturer: Cleaver Brooks, Aqua-Chem Inc., Milwaukee, Wisconsin, U.S.A.
  • Model: CB-100-200
  • Serial Number: L-71372
  • Manufacturing Date: 8/5/81
  • UL File Number: R-991648


Capacity Ratings:


  • Horsepower: 250 HP
  • Maximum Pressure: 150 PSI
  • Input: 8,369,000 BTU/HR
  • Fuel Type: Natural Gas
  • Blower Motor: 10 HP


Electrical Requirements:


  • Main Power: 230 Volts, 3-Phase, 60 Hz, 28 Amp
  • Minimum Circuit Ampacity: 35 Amp
  • Maximum Circuit Protection Rating: 112 Amp
  • Control Circuit: 120 Volts, 1-Phase, 60 Hz, 7 Amp
  • Oil Pump Motor: 115 Volts, 1-Phase, 60 Hz, 7 Amp


Construction: Packaged steam boiler with factory-insulated jacket on skid base


Made In: USA (Milwaukee, Wisconsin)


Patents: U.S. Patents 3,205,865, 3,941,566, 3,056,389, 3,079,881

Specifications

ManufacturerCleaver Brooks
ModelCB-100-200
Year1981
ConditionUsed
Serial NumberL-71372
Stock NumberBSCB250HP246
* BrandCleaver Brooks
* ModelCB-100-200
* Serial NumberL-71372
* Manufacturing Date8/5/81
* UL File NumberR-991648
* Fuel TypeNatural Gas
* Horsepower250 HP
* Maximum Pressure150 PSI
* Equipment TypePackaged Steam Boiler